Health Res Develop 2024, 2(2): 58-69 Back to browse issues page
Investigating the physical, chemical and microbial quality of drinking water of water desalination devices with reverse osmosis process in Gonabad city in 2019
Ahmad Zarei1 , Mehdi Qasemi2 , Zahra Basiti3 , Maryam Afkar sorond3 , Saeed Naghizade3 , Sajjad Abedi3 , Hasan Reza Rokni * 4
1- gonabad university of medical science, a.zarei.tums@gmail.com
2- gonabad university of medical science, mehdi-544@yahoo.com
3- gonabad university of medical science
4- gonabad university of medical science, h.r.rokni@gmail.com , h.r.rokni@gmail.com
Abstract:   (412 Views)
Background and purpose: Access to safe drinking water sources is a very important and vital issue that every year 1.1 billion people in the world do not have access to safe drinking water sources. Water softeners play a significant role in providing the water needed by communities, and due to the increase in water consumption and the decrease in natural fresh water resources, this role becomes more prominent day by day. The purpose of this study is to investigate the drinking water quality of Gonabad water desalination devices in 2019 and to compare the quality of its output water with national and WHO drinking water standards.
Materials and methods: This study was performed by sampling inlet and outlet water of desalination plants working process in Gonabad during 3 times in 2020. Total hardness, electrical conductivity (EC), total dissolved solids (TDS), temperature, pH, fluoride, nitrate, chloride, sulfate, sodium, calcium, magnesium, potassium and microbiological parameter HPC were investigated. Data analysis was performed by Excel version 2016.
Results: Chloride, total hardness, TDS was less than optimal and fluorine was lower than Iranian or WHO guidelines in both centers. And the concentration of other chemical and physical parameters studied was within acceptable limits. In desalinated water, most of the studied quality parameters were reduced by about 65.50, 53.43 and 68.90% compared to the incoming water in the three centers, and the output values were within the standard range.
Conclusion: Desalination plants have a high efficiency in providing safe drinking water based on qualitative standards.
Keywords: Water quality, Water treatment, Desalination systems, Gonabad
Full-Text [PDF 857 kb]   (114 Downloads)    
Type of Study: Original | Subject: Special
Received: 2024/04/22 | Accepted: 2024/09/16 | Published: 2024/09/16
References
1. Mahvi AH, Mazloomi S. Desalination for providing Healthy Drinking Water(Guideline on Health and Enviromental Aspects of Desalination Process). a: Ava Ghalam publication; 2009.
2. Diersing N. water Quality: Frequently Asked Questions. Florida Keys National Marine Sanctuary Published. 2009.
3. Aghababaei N. Evaluation of the Physical, Chemical and Microbial Qualiti of Desalination water provided by the private sector in saveh. JSUMS. 2016; 23(5): 810-7. [DOI:10.21859/sums-2305810]
4. Majdi H, LGheibi, Soltani T. Evaluation of the physicochemical and Microbial Quality of Drinking Water of villages in Takab Town in West Azerbaijan in 2013. J Rafsanjan Univ Med Scie. 2015;14(8):631-42.
5. Tavanghar A, Naimi N, alizadeh H et al. Evaluation of water treatment systems performance available in Bojnurd city. NKUMS 2013;5(5):1107-19. [DOI:10.29252/jnkums.5.5.S5.1107]
6. Pirsaheb M, Moradi M, Sharafi K et al. Evaluation of the relationship between microbial quality of drinking water and the cross-sectional outbreak of related diseases-case study kangavar city(2005-2009). J. HEALTH Sci. 2013;1(2): 9-16.
7. DehghanI M, NoorMoradi H, Hashemi H et al. Evaluation of the physical ,chemical and biological quality of water intake and outlet of reverse osmosis processes and multi-stage evaporation for drinking Journal of faculty of medicine. J Environ Public Health 2022;13:36-42.
8. Keramati HA, Mahvi AH, Abdulnezhad L. The survey of physical and chemical quality of Gonabad drinking water in spring and summer of 1386. Intern. Med. J. 2007; 13(3): 25-32.
9. Deghani M, Doleh M, Hashemi H et al. The quality of raw and treated water of desalination plants by reverse osmosis in Qeshm. J. health dev. 2013;2(1): 33-43.
10. Afsharnia M, Shams M, Qasemi M et al. Evaluation of the chemical quality of water of Gonabad city water desalination in the first half of 90th. The 16th national conference on enviromental health in Iran. 2013.
11. Yari A, Safdary M, Haddian L, Babakhani M. Evaluation of the Physical, Chemical and Microbial Qualiti of Desalination water provided by the private sector in Qom. Qom Univ. Med. Sci. J. 2007;23 (5): 810-7. [DOI:10.21859/sums-2305810]
12. Naeemi N, Tavanghar A, Alizadeh H, Ghorbanpour R. Evaluation of the performance of water purification devices in the city of Bojnour in 2013. The 16th national conference on enviromental health in Iran. 2013.
13. Sh ka, M T, H MH. Evaluation of the physical and chemical quality of drinking water of sarein city with national and international standards. EMSD. 2019;14(1): 36-50.
14. Shams M, Qasemi M, Afsharnia M et al. Chemical and microbial quality of bottled drinking water in Gonabad city, Iran: Effect of time and storage conditions on microbial quality of bottled waters. MethodsX. 2019 ;6 :273-7. [DOI:10.1016/j.mex.2019.02.001] [PMID] []
15. Naghizadeh A, Kamranifar M, Masoudi F. Chemical and microbiological quality of desalinated waters in Birjand city, Iran. J. Water Sanit. Hyg. Dev. 2019;9(1):64-70. [DOI:10.2166/washdev.2018.210]
16. Malakootian M, Momeni J. Quality Survey of Drinking Water in Bardsir ,Iran 2009-2010. J Rafsanjan Univ Med Scie. 2012;11(4):403-10.
17. Dindarlou K, Alipour V, Farshidfar G. Chemical quality of drinking water in BandarAbbas. Hormozgan Med J. 2006;10(1):57-62.
18. Tariqi M, arjaghy Sk, Fataei L. Changes in physical and chemical parameters of raw water ,waste water treatment plant and drinking water networ in Ardebil. EMSD. 2019;319-325.
19. Institute Of Standards and Industrial Research Of Iran [Physical and Chemical specifications 1053 (persian)]. 5th ed. Tehran: Institute of Standard and Industrial Research of Iran;1997.
20. Standard Methods for the Examination of Water and Wastewater. 20th ed. American Public Health Association 1999.
21. Babaee A, Ghaffarizade F, Noormoradi H. Investigating the microbial quality of outgoing water from water purification devices in Abadan city. Journal of Ilam University of Medical Sciences. 2014; 22:132-40.
22. Asad zade N, Langarizade M, Alizade M. The performance of reverse osmosis device in water purification of dialysis centers of Imam Ali Hospital. Journal of North Khorasan University of Medical Sciences. 2016;8(1):7-16. [DOI:10.29252/jnkums.8.1.7]
23. Noori M, Jafari N, Mollaee S. Evaluating the quality of water output from water desalination devices and water tankers in Qom city and comparing it with national and WHO standards. Journal of Environmental Health Engineering. 2020;8(4):465-76 [DOI:10.52547/jehe.8.4.465]
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA

Ethics code: IR.GMU.REC.1399.037



XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Zarei A, Qasemi M, Basiti Z, Afkar sorond M, Naghizade S, Abedi S et al . (2024). Investigating the physical, chemical and microbial quality of drinking water of water desalination devices with reverse osmosis process in Gonabad city in 2019. Health Res Develop. 2(2), 58-69. doi:10.61186/jhrd.2.2.58
URL: http://jhrd.trjums.ac.ir/article-1-59-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 2, Issue 2 (7-2024) Back to browse issues page
پژوهش و توسعه سلامت Health research and development
Persian site map - English site map - Created in 0.06 seconds with 36 queries by YEKTAWEB 4679